Explosion-proof analysis shelter
- Model: PXK
- Brand: Hualong
- Category: Explosion-proof analysis shelter
Consultation Hotline
Product Introduction
Explosion-proof analysis shelterAlso Known AsExplosion-proof shelter、Explosion-proof Station House、Explosion-proof InstrumentArea、Analysis Shelter、inLineAnalysis Shelter,IssolutioninLineAnalytical Instruments And BudgetprocessingsysteminExplosive GasEnvironmentNextsafetyShouldUsers的MatchingElectricalequipmentintegrateCost,containingShelterFoundationStructure、SelfControlsystem、power distributionsystem、Lighting System、ConnectLockAlarm System、Gas Detectionsystem、TemperatureControlventilationsystem。In recent years, it has been widely used with VOCS analyzers and CEMS flue gas online analysis in industries such as chemical, petroleum, and environmental monitoring.。

Explosion-proof analysis shelterclassification
FlameproofAnalysis Shelter
LocationsWithEnergizedequipmentAllForIndependentlyRemain的explosion-proofComponents,ComponentsAllEnhancedHighlyExplosion-proof Certification,ForIndependentlyRemain的explosion-proofProduct。
detailedLearn,RecommendRead:Flameproof Type Explosion-proof Analytical House
Positive PressureExplosion-proof analysis shelter
RoofDomesticUpInstallationnonexplosion-proof的Analyzer And variousInstrumentTableCabinet;operationPositive PressuresystemMakeRoofDomesticDescribeCostPositive Pressure,nonexplosion-proofPartVentilationElectricoperation。
detailedLearn,RecommendRead:Positive Pressure Type Explosion-proof Analytical House
Explosion-proof analysis shelterfeature
ZhengzhouHualongExplosion-proof ElectricalManufacturerProduction的PXKExplosion-proof analysis shelterhavefollowingfeature:
Explosion-proof shelterfunctionmodulestructureIntelligent,containingSelfControlsystem、power distributionsystem、Lighting System、ConnectLockAlarm System、Gas Detectionsystem、TemperatureControlventilationsystem,all undergoexplosion-proofprocessing And Explosion-proof Certification,processComplex,achieveCustomeron-siteintegrateIncontrol、ConditioningDegreeIndexVolatile、processanalysis、InstrumentTablemonitoring;
Explosion-proof shelterperformanceMoreSampleIntelligent
explosion-proof、Dust-proof、Waterproof、Anti-static、Corrosion Resistant、anti-spark、anti-VibrationInteraction;
constant temperature、constantHumidity
ConfigureCoolingWarmTypeExplosion-proof Air Conditioner,ensureInvincibleSameStationWeatherEnvironmentNextequipmentnormaloperation;
Real-time Monitoring,safetyperformanceHigh
ExploreMeasureApplianceDetectionAchieveflammableConcentration,OxygenStationConcentrationEtc.ExceedStandardCanautomaticStartRiskMachineAdvanced IndoorAerospaceStationCycleEnvironmentalRareExplain, And DevelopOutputAudible and Visual AlarmTrustedno.,RelatedShouldAlarmTrustedno.CanReserveCustomer FirstExplosion-proof Junction Box,SendTo FinalendintegrateControlRoom。
Explosion-proof analysis shelterparameter
Explosion-proof analysis shelterConfiguration List And ShelterHousingparameter。


Explosion-proof analysis shelterFineEnergy-saving
Explosion-proof analysis shelterOverseasDescribestructure
ShelterHousingByFrameRack,DomesticOverseasWall,RoofTop,Bottom PlateEtc.Componentscomposition。The frame skeleton is welded from section steel; inner and outer wall panels are made of 304 stainless steel plate or carbon steel with plastic spraying, with plate thickness customized per customer requirements; 75mm flame-retardant insulation material is filled between wall panels; the roof is a gable roof with lifting rings for hoisting; the floor is 4mm thick anti-slip plate with anti-static treatment, wear-resistant and durable.。

Explosion-proof analysis shelterSelfControlsystem
SafeCalledexplosion-proofPositive Pressure Controller,intelligentSafeAutomatedTriggerTouchOperate。3.5-inch true-color large screen display, with five control channels: intake valve, exhaust valve, temperature control valve, alarm, and user power; system parameters such as purge time, pressure upper limit, pressure upper-upper limit, pressure lower limit, pressure lower-lower limit, and temperature upper limit can be set; overvoltage protection, overcurrent protection, and reverse connection protection.。

Explosion-proof analysis shelterpower distributionsystem
power distributionsystemByexplosion-proofPublicUserspower supplyDistribution Box、explosion-proofUPSDistribution Box、explosion-proofPublicTogetherpower supplyJunction Box、explosion-proofUPSpower supplyJunction Box、explosion-proofTrustedno.Junction Box、explosion-proofrepairpower supplySocketEtc.Componentscomposition。

Explosion-proof analysis sheltersafetyDetectionAlarm System
safetyDetectionAlarm SystemByexplosion-prooftoxicGas DetectionAppliance、explosion-proofflammableGas DetectionAppliance、explosion-proofOxygenStationConcentrationDetector、explosion-proofAudible and Visual Alarm Lamp And LinkedLockdevicecomposition。The detection probes and signal transmitters are integrated into a single structure, with local display meters and remote transmission of alarm analog signals.。All detectors are equipped with on-site audible and visual alarm devices, which trigger abnormal interlock alarms and transmit signals remotely to the DCS control room.。
Explosion-proof analysis shelterLighting System
Lighting SystemByIndoorexplosion-proofSafePlastic FluorescentLightLight、explosion-proofShouldEmergencyLight And OutdoorExplosion-proof LightingLightcomposition。In emergency conditions, emergency lights are activated with an emergency duration of 90 minutes, providing both normal and emergency lighting functions.。
Explosion-proof analysis shelterTemperatureControlventilationsystem
TemperatureControlventilationsystemByexplosion-proofCoolingWarmair conditioner、explosion-proofShaftMainstreamRiskMachine And DuringFilterdevicecomposition。The explosion-proof heating and cooling air conditioner regulates indoor temperature with constant temperature and humidity functions; fan openings are equipped with protective devices to prevent rain and insects from entering; exhaust fans can be started manually or automatically—manual mode forces the fan on for ventilation, while automatic mode is controlled by PLC for start/stop; on-site instrument air or safe site air can be used, providing a safe and reliable gas source to the shelter through purge filtration devices.。
Explosion-proof analysis shelterCertificate
Explosion-proof analysis shelterCertificatedivided intoExplosion-proof Certificate And SafeCountryIndustryProductlicenseCertificate。RecommendRead:Such aswhatAdvanced Explosion-proof CertificateCheckConsult And SafeCountryIndustryProductlicenseCertificateCheckConsult?
Explosion-proof analysis shelterdrawings
Explosion-proof analysis shelterTopIgnoredDiagram

Explosion-proof analysis shelterDomesticArrangeDiagram

Explosion-proof analysis shelterOverseasArrangeDiagram

Explosion-proof analysis shelterInvincibleBasicReferenceDiagram

FAQ
Explosion-proof analysis shelterprice?
Answer: The specific price of an explosion-proof analysis shelter depends on the shelter size, configuration list, and parameters for quotation.。The more configurations and the better the brand selected, the higher the price of the shelter.。The price of a conventional 3m x 3m shelter with internal stainless steel and external carbon steel is generally around 80,000 to 120,000 RMB.。
How to solve the problem of excessive temperature inside an explosion-proof analysis shelter??
Answer: Explosion-proof analysis shelters are equipped with explosion-proof heating and cooling air conditioners of different capacities based on shelter size to address the issue of excessive temperature.。The larger the shelter size, the greater the air conditioner capacity.。For example, a 3m x 2.5m shelter is equipped with a 1P air conditioner; a 3m x 4m shelter is equipped with a 1.5P air conditioner.。
Precautions for on-site use of explosion-proof analysis shelters.?
Answer: For non-explosion-proof electrical equipment installed inside an explosion-proof analysis shelter, please complete installation and commissioning in a safe area. All explosion-proof electrical equipment must not be operated with the cover opened while energized in the hazardous area. For positive-pressure type shelters, it is strictly prohibited to open the door and operate without pressure while energized in the hazardous area.!
What manufacturers produce explosion-proof analysis shelters??
Answer: Currently, domestic manufacturers of explosion-proof analysis shelters are of mixed quality. When purchasing, be sure to check whether the manufacturer's production qualifications and product certificates are complete.。Brand manufacturers of explosion-proof analysis shelters include Huarong, Helong Explosion-Proof, and Hualong Explosion-Proof.。
Technical Parameters
| Product Model | PXK |
| Product Brand | Hualong |
| Manufacturer | Henan Hualong Electrical Equipment Co., Ltd |
| Product Categories | Explosion-proof analysis shelter |
ShouldUsersField
FoundationProducts widely used infollowingindustry And location:
Applicable Industries
- Petrochemical:Oil Refinery、Chemical Plant、Oil Field、Natural Gasstation、Oil DepotEtc.Flammable and Explosivelocation
- CoalcoalMine:Coal Mineunderground、Coal Preparation Plant、CoalChemicalEtc.WithExplosive GasEnvironment
- Electric Power & Energy:power plant、Substation、wind power generation、solarAbilitypower stationEtc.
- MetallurgySteel:SteelFactory、AluminumFactory、CopperFactory、MetallurgyWorkshopEtc.
- pharmaceuticalmanufacturing:Pharmaceutical Factory、pharmaceutical intermediateStructure、biologicalEngineeringEtc.
- Grain Logistics:grain reserve depot、Flour Mill、Feed MillEtc.Dust ExplosionHazardous Location
applicableHazardous Area
- Explosive GasEnvironment:Zone 1、Zone 2Hazardous Location
- Combustible DustEnvironment:Zone 20、Zone 21、Zone 22
- IIA, IIB, IIC explosive gas environments
- Temperature Group: T1-T6 (Maximum Surface Temperature ≤85℃)
Ordering instructions
ForensureyouorderProductmeet on-siteUseRequirements,Please inwhen orderingprovidefollowinginformation:
orderingDemandprovideinformation
- Product Model、specification And quantity
- Rated Voltage、Rated Current、Number of Poles
- Explosion-proof Markingrequirements
- Ingress Protection (IP) Ratingrequirements
- circuitquantity And EveryProductioncircuitCurrent、functionConfigure
- Inlet and Outlet Wire Methods
- Inlet and Outlet Thread Specifications and Quantity
- Enclosure Materialrequirements(Cast Aluminum/Steel Plate/Stainless Steel)
- IsnoneedAmmeter、Voltmeter、Indicator LightEtc.attachPlusfunction
Service Commitment
- FoundationCompanyProductstrictaccording toNational StandardProduction,Quality AssuranceRegular18ProductionMonth
- ProductOutputFactoryFrontAllAfter Strict Testing,Attached withhProductCertificate of Conformity、ManualEtc.documents
- can be based on user needsprovideTechnical Support And on-siteInstallationguidance
- provideComprehensive的After-sales Service,Warranty PeriodDomesticfreerepairreplacement