Explosion-proof cabinet air conditioner

  BJKTExplosion-proof cabinet air conditioner Mainly forPetroleum、Chemical、FutureGasEtc.ContainWithExplosive GasEnvironmentIn,forInstallationWithHeatingQualityGreater、temperatureSensitiveSenseelectricalcomponent(Such asGreaterPowerInverter)的Explosion-proof Power Distribution Cabinet(controlCabinet)In,solutionCabinetDomesticLowerTemperatureWithmeetElectricalcomponent的normalUse。

  Explosion-proof cabinet air conditionerWorking Principle

  MachineCabinetair conditionerThroughDomesticOverseasTwoProduction Completely IndependentlyRemain、IsolationEliminate的AerospaceStationCycleEnvironmentalHandleMachineCabinetInternal的AerospaceStationCooling,meanwhileHandleCabinetDomestic的HeatQualityThroughHeatAlternatingChangeDriveSpreadOutputCabinetOverseas,therebyProtectionCabinetDomesticelectricalcomponentinUpControl的temperaturerangeoperation,meanwhileMachineCabinetair conditionerhaveRemoveHumidityfunction,guaranteeMachineCabinetInternalWithPhilosophyIdeal的temperature And humidity。

Explosion-proof cabinet air conditionerWorking PrincipleIndicateAccidentDiagram

       Explosion-proof cabinet air conditionerTechnical Parameters

Explosion-proof cabinet air conditionerparameterTable

  Explosion-proof cabinet air conditionerInstallationIndicateAccidentDiagram

1.jpg

     explosion-proofMachineCabinetair conditionerCertificate

Explosion-proof cabinet air conditionerCertificate

       Explosion-proof cabinet air conditionerOperating Instructions  

       1.Internalparameterdescription And setup

  ExcellentIndicatePanelAccordingKey:setupKeyS,Start-stopKey,SupremeTurnKey,NextTurnKey

  2.temperaturePointsetupmethod

  ExcellentIndicatePanelAccordingKey:setupKeySET,someAccordingKeyUpWithincreasedPlus Or ReduceLesstemperatureEquipmentStableValue,Start-stopKeyRST,ThereforeControllerPower OnAfter-salesProcessingInStandbyMachinestatestate,AccordingOneNextRSTKeyExcellentIndicateONTwoSecondAfter-sales,OpenStartIndustryOperating。During operation, press the RST key once, and after "OFF" is displayed for 2 seconds, output stops and the unit enters standby mode.。

  3.MenuUnitparametersetupmethod

  AccordingsetupKeySETexceed3Second,EntryMenuUnitExcellentIndicate,QuiteTogetherScreenOutputOn-siteF01CodeWhen,AccordingOneNextsetupKeySET,ThereforeWhenExcellentIndicate的ForChooseFrontWorking StateEquipmentStableValue,AccordingKeyUpModificationVariableEquipmentStableValue,setupPerfectShouldparameter,AccordingSETKeyReturnCircuitF01,AccordingUpSupremeNextSwitchF01-F11VariousMenuUnitCan,WithSupremeAsmethodAdvanced setup。After all settings are complete, press the SET key for 2 seconds to save and exit, or wait 15 seconds without any key operation to return to normal operating status.。

  4.temperatureLaboratoryTruly

  QuiteMeasurementtemperature And Standard Temperature With Deviation When,UseThereforefunction,UpWithWillMachineApplianceMeasurementValue And StandardtemperatureAdjustmentOneCausing。Calibrated temperature = temperature before calibration + calibration value. 。

  constant temperaturecontrol And over-temperatureAlarmfunction:

  QuitetemperatureMeasurementValue≥SystemCoolingshutdowntemperature+SystemCoolingCircuitdifferenceWhen,SystemCoolingRelaySuctionOverall,compressorStart;

  QuitetemperatureMeasurementValue<temperaturesetupPointWhen,SystemCoolingRelayDeterminationOpen,compressorPay AttentionClosed。

  QuitetemperatureMeasurementValue≤SystemHeatshutdowntemperature-SystemHeatCircuitdifferenceWhen,SystemThermal RelaySuctionOverall,SystemHeatoutput;

  QuitetemperatureMeasurementValue>SystemHeatshutdowntemperatureWhen,HeatThermal RelayDeterminationOpen,SystemHeatStopoutput。

  AlarmModelFormNext:QuitetemperatureMeasurementValue≥over-temperatureAlarmSupremeLimitedWhen,AlarmRelaySuctionOverall,AlarmStart;

  QuitetemperatureMeasurementValue≤over-temperatureAlarmNextLimitedWhen,AlarmRelaySuctionOverall,AlarmStart。

  5.compressorextendWhenStartTime

  SystemCoolingModelFormNext:OneSecondaryVentilationElectric,ifQuiteFronttemperatureGreaterIntemperatureEquipmentStableValue+SystemCoolingCircuitdifferenceWhen,compressorwill notRemain Namely StartSystemCooling,needoperationEquipmentStable的extendWhenTimeAfter-salesAbilityAbilityStart。

In heating mode, upon initial power-on, if the current temperature is less than the temperature set value - heating differential, the heating equipment starts heating immediately.。

  compressorRelated Next Two SecondaryStartPositionArea的DowntimeAreaIsolationGreaterIncompressorextendWhenStartTimeEquipmentStableValueWhen,compressorRemain Namely Start;

  compressorRelated Next Two SecondaryStartPositionFront的DowntimeAreaIsolationSmallIncompressorextendWhenStartTimeEquipmentStableValueWhen,compressorStartDemandoperationPerfectLocationssetup的compressorextendWhenStartTimeEquipmentStableValueAfter-sales,MachineApplianceAbilityAbilityStart。The delay time is calculated from the moment of shutdown.。

  6.High、Low TemperaturesetupSupremeLimited

  F07 And F06的setupSupremeNextLimitedValue,LimitedStable了TemperatureControlAppliancetemperaturesetupPoint的EquipmentStablerange。

For example: If F07 is set to +15 and F06 is set to -10, the cooling stop temperature can only be set below 15, and the heating stop temperature can only be set above -10. To broaden the range, the set values of F07 and F06 must be adjusted first. 。

  7.faultCode

  SensorFault Alarm:VentilationElectricstatestateNext,SensorDeterminationLineWhen,LED Flash Blinking Indicates"---",Short CircuitWhenExcellentIndicate"HH",SensorfaultstatestateNext,compressorAccordingStop15ClassBell,operation15ClassBell的methodCycleEnvironmentalIndustryOperating。

  8.ExceedQualityExtentAlarm

  QuiteSensortemperatureGreaterIn110℃When,ExcellentIndicateHHH;QuiteSensortemperatureSmallIn-40℃When,ExcellentIndicateLLL。

      Explosion-proof cabinet air conditionerInstallationSteps

  1.ClearPointAttachment And StandardFacilityInstallationtools

  2.inInstallationAspectsSupremeDrawOutputCabinet DoorOpenHoleIndicateAccidentDiagram,WillFemaleAffectPartCutCutDrop。

3. Use shock-absorbing sealing rubber strips to seal between the air conditioner and the cabinet installation surface according to the designed sealing surfaces.。

4. Securely fix the air conditioner onto the cabinet mounting surface using installation screws.。

5. Fill the gap between the air conditioner and the cabinet mounting surface with waterproof structural sealant.。

6. During installation, maintain a minimum clearance of 100mm between the indoor-side air outlet and any front object, and a minimum clearance of 500mm between the outdoor-side air outlet and any front object.。

7. When installing the water pipe, bend it into a double U-shape and secure it, then route the outlet externally.。

8. Perform a confirmation inspection after installation. Do not use the explosion-proof cabinet air conditioner in environments with high oil contamination, high corrosivity, ambient temperatures exceeding 55°C, or humidity exceeding 95%. Ensure the product's tilt angle does not exceed 3° after installation.。

9. After installation of the explosion-proof cabinet air conditioner, ensure it remains upright for 30 minutes before powering on.。

  Explosion-proof cabinet air conditionerPrecautions

  1.LocationsWithcircuitConnectionmustcompliantNational Standard的Regulations,power supply的Voltage、Frequency And AsQualitymustcompliantFoundationProduct的UseRegulations。

2. Installation must be carried out by trained professionals.。

3. Installation and electrical wiring of the cabinet air conditioner must be strictly performed by professionals in accordance with the relevant provisions of this manual.。

4. The ground wire must be properly connected and reliably grounded. Do not connect the ground wire to gas pipes, water pipes, lightning rods, or telephone lines. Poor grounding may result in electric shock hazards.。

5. It is prohibited to tap into or extend the power cord, and it is prohibited to apply heavy pressure, heat, or pull on the power cord.。