Maintenance plan and precautions for explosion-proof analysis shelters

For a long time, due to the neglect of maintenance of explosion-proof analysis shelters, many explosion-proof shelters have safety hazards. Below, Hualong Explosion-proof will explain in detail the maintenance plans and precautions for explosion-proof analysis shelters.。

Explosion-proof analysis shelter

Explosion-proof analysis shelterMaintenancesolution

  1. Regular InspectionExplosion-proof analysis shelterpower distribution、Alarm、ventilationEtc.systemequipment的Integrity,Such asWithincompleteloss And DamageShould And Whenreplacement。

  2. Check the shelter shell for any abnormalities. If there are issues such as deformation or damage, handle them promptly.。

  3. Check all explosion-proof cable seals entering and exiting the analysis shelter for looseness or abnormalities to prevent combustible gases from hazardous environments from entering the piping.。

  4. Test whether the connecting lines have poor contact or breakpoints.。

  5. UseIn的Explosion-proof analysis shelterShouldEach MonthRegular InspectionOneSecondary,ClassChipLoad责ElectricIndustryShouldEveryFutureInspectOneNext And Record。

  6. The power distribution system should be inspected and recorded once per quarter.。

  7. Such asUsePositive Pressure Type Explosion-proof Analytical House,alsoDemandInspectPositive Pressure Explosion-proofController的Undervoltage、Overvoltage ProtectionIsnoreliable,provideAir Source的equipmentAlsoCriticalregularlyfaultDrainCheck

  8. InspectOverseasAroundElectric、Station的Operating State,Strictlyanti-Electric、StationOutputOn-siteAbnormal。Check whether the instrument air supply is normal.。

  9. Check whether the sample gas carries water or liquid during the pretreatment process. If abnormal, stop the machine to troubleshoot.。Check whether the instrument operating status and DCS display (including historical curves) have any abnormalities.。

  10. Check whether the vent line is abnormal.。Check whether the configurations, facilities, explosion-proof equipment connections, piping connections, working status, and flow/pressure indications inside the analysis shelter have any abnormalities.。

Explosion-proof analysis shelterPrecautions

Strictly ProhibitnonprofessionalElectricalengineer And 闲ImpuritiespersonnelOperateCommissioningExplosion-proof analysis shelter,nonprofessionalpersonnelPlease inExplosion-proof analysis shelterManufacturertrainingAfter-salesUse

  1. It is strictly forbidden to store or temporarily place any combustion-supporting, flammable, or combustible items inside the explosion-proof shelter, and it is strictly forbidden to store or temporarily place highly corrosive items.。

  2. During maintenance and repair, before entering the analysis shelter, personnel must turn on the flameproof axial-flow exhaust fan outdoors through the explosion-proof switch.。

  3. When working inside the shelter, do not close the door completely.。If the door is closed and a dangerous or combustion abnormal state occurs, push the door push rod inside the shelter outward, and the door will open to protect personal safety.。

  4. All explosion-proof electrical equipment inside the explosion-proof shelter is strictly forbidden to be disassembled, loosened, or opened while energized.。Only after power is cut off and the portable combustible gas alarm tests qualified can such operations proceed.。

  5. If indoor and outdoor lighting or emergency lamps are found not to be lit, after powering off and checking that there is no combustible hazardous gas in the environment, replace the bulb or fluorescent lamp.。

  6. systemConfigure的Explosion-proof LightingInteractionStrengthDistribution Box,Cut忌EnergizedAdvanced processing。Strictly comply with safe electricity usage regulations.。

  7. After replacing pretreatment components in the system or suspecting a leak somewhere, a strict leak check of the system must be conducted under the supervision of personnel.。Strictly ProhibitsystemLeak。

  8. If operational quality issues arise in the system and the user is unable to handle them, the manufacturer should be contacted promptly to prevent the accident from escalating.