Positive-pressure explosion-proof control cabinet
- Model: PXK51
- Brand: Hualong Electric
- Category: Explosion-proof positive pressure cabinet
Consultation Hotline
Product Introduction

According to the provisions of GB3836.1 "Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements", GB3836.2 "Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Flameproof Enclosures 'd'", GB3836.5 "Electrical Apparatus for Explosive Gas Atmospheres - Part 5: Pressurized Enclosures 'p'", and GB3836.15 "Electrical Apparatus for Explosive Gas Atmospheres - Part 15: Electrical Installations in Hazardous Areas (Other Than Mines)", the pressurized explosion-proof electrical control cabinet has the explosion-proof marking: ExpxIICT4.。This positive-pressure explosion-proof control cabinet has been inspected and approved by Nanyang Explosion-Proof Electrical Research Institute, and has obtained the product explosion-proof certificate.
Model And basicparameter
Model:PXK51
Rated Current: 630A
Ingress Protection (IP) Rating: IP65
Explosion-proof Marking: ExpxIICT4
Air SourceVariousVarious: Clean、safetyAerospaceStation
Air Sourcepressure: 0.4~0.8 MPa
operationPositive Pressure: 50 Pa~300Pa
Positive PressureCavityNetAsArea: ≤510 L+510L+100L
BlowingSweepTime: 30min
High PressureDrainStation: GreaterIn400Pa
LowPressureAdvancedStation、Alarm: SmallIn50Pa
structure And Principle
Positive-pressure explosion-proof control cabinetmainlyWithElectricControlCabinet、StationControlCabinet、LeftOperatePlatformThreeProductionPart。Positive-pressure explosion-proof control cabinetMainStructureByPositive PressureEnclosure、Positive PressureStationLinesystem、Flameproof TypeControl BoxEtc.SeveralPartcomposition, And Positive Pressure Explosion-proofCabinetRelatedSame。
The pressurized enclosure is an airtight enclosure made of 2.5mm stainless steel plate formed by folding and seam welding.。Because it can maintain the pressure of the internal protective gas higher than the pressure of the external explosive gas atmosphere, it can effectively prevent external explosive gas mixtures from entering the interior of the enclosure.。A red "ExpxⅡCT4" marking plate is located in a prominent area on the front of the pressurized enclosure.。
inPositive PressureEnclosureSupremeInstallationWithifDryCable EntryTriggerOutputdevice、StationLineConnector、ElectricApplianceSwitchEtc.,Thesesomedevice的InstallationInvincibleBreakBadPositive PressureEnclosure的Gas Tightperformance;
Positive PressureStationLinesystemByDuringFilterReducePressureUnitComponents、Energy-savingMainstreamValve、Explosion-proof electricMagneticValve、PipeLine And Connectorcomposition。The pressure inside the pressurized enclosure is controlled by the precision pressure-reducing valve, throttle valve, and inlet and exhaust solenoid valves in linkage, keeping the pressure in each pressurized enclosure stable between 100Pa and 300Pa.。
The protective gas is transmitted through valves, piping, etc., filtered and pressure-reduced to become pure micro-pressure gas that enters the pressurized enclosure. After 30 minutes of purging, the concentration of any explosive gas that may exist inside the enclosure is diluted to a safe range, and positive pressure is maintained, making the interior of the pressurized enclosure a safe place for electrical installation.。
Flameproof TypeControl BoxLoadSupplied To Positive PressureEnclosureDomestic的MainContactorLineRingProvidepower supplySource, And ForPositive PressureEnclosureDomestic的Positive PressureValueAdvanced Detection,achieveLowPressure、High PressureAlarm、LowPressureautomaticAdvancedStation、High PressureautomaticDrainStation。When the pressurized enclosure has been purged for 30 minutes and the pressure inside the enclosure is greater than 50Pa, the main contactor inside the pressurized explosion-proof control cabinet can be energized to operate and supply power to the control relays of other electrical equipment in the driller's cabin. When the pressure is less than 50Pa, the system automatically alarms and automatically opens the inlet solenoid valve for air intake; when the pressure is higher than 200Pa, the exhaust solenoid valve opens for exhaust.。

UsesafetyRequiredWell-known
1.UsePositive-pressure explosion-proof control cabinetPositionFront,PleaseCertificationTrulyReadUser ManualDocument。
2. The flameproof control box of the pressurized explosion-proof control cabinet and the power supply of the pressurized enclosure adopt electrical interlocking. Only after the pressurized enclosure has been purged for 30 minutes and positive pressure has been established will the main power contactor coil close, allowing power to be supplied inside the pressurized enclosure.。
3. It is strictly prohibited to open the cover of the pressurized explosion-proof control cabinet while it is live. If opening for inspection or maintenance is required, the upstream power supply should be disconnected beforehand.。
4. The air source for the pressurization control system must be purified compressed air or other non-combustible gas (nitrogen N2).。
5. If explosion-proof components equipped with the pressurized explosion-proof control cabinet are damaged, contact our company for repair or purchase.。
6. Components and structures that affect explosion-proof performance must not be replaced, changed, or adjusted arbitrarily.。
7. Components must not be arbitrarily installed on the shell of the pressurized enclosure.。
8. When the positive pressure value drops below 50Pa and the low-pressure alarm begins, personnel must immediately take measures to raise the positive pressure value to 50Pa, or cut off the power for inspection. Only after the fault is cleared and the pressurization system returns to normal can the operation be restarted.。
Technical Parameters
| Product Model | PXK51 |
| Product Brand | Hualong Electric |
| Manufacturer | Henan Hualong Electrical Equipment Co., Ltd |
| Product Categories | Explosion-proof positive pressure cabinet |
ShouldUsersField
FoundationProducts widely used infollowingindustry And location:
Applicable Industries
- Petrochemical:Oil Refinery、Chemical Plant、Oil Field、Natural Gasstation、Oil DepotEtc.Flammable and Explosivelocation
- CoalcoalMine:Coal Mineunderground、Coal Preparation Plant、CoalChemicalEtc.WithExplosive GasEnvironment
- Electric Power & Energy:power plant、Substation、wind power generation、solarAbilitypower stationEtc.
- MetallurgySteel:SteelFactory、AluminumFactory、CopperFactory、MetallurgyWorkshopEtc.
- pharmaceuticalmanufacturing:Pharmaceutical Factory、pharmaceutical intermediateStructure、biologicalEngineeringEtc.
- Grain Logistics:grain reserve depot、Flour Mill、Feed MillEtc.Dust ExplosionHazardous Location
applicableHazardous Area
- Explosive GasEnvironment:Zone 1、Zone 2Hazardous Location
- Combustible DustEnvironment:Zone 20、Zone 21、Zone 22
- IIA, IIB, IIC explosive gas environments
- Temperature Group: T1-T6 (Maximum Surface Temperature ≤85℃)
Ordering instructions
ForensureyouorderProductmeet on-siteUseRequirements,Please inwhen orderingprovidefollowinginformation:
orderingDemandprovideinformation
- Product Model、specification And quantity
- Rated Voltage、Rated Current、Number of Poles
- Explosion-proof Markingrequirements
- Ingress Protection (IP) Ratingrequirements
- circuitquantity And EveryProductioncircuitCurrent、functionConfigure
- Inlet and Outlet Wire Methods
- Inlet and Outlet Thread Specifications and Quantity
- Enclosure Materialrequirements(Cast Aluminum/Steel Plate/Stainless Steel)
- IsnoneedAmmeter、Voltmeter、Indicator LightEtc.attachPlusfunction
Service Commitment
- FoundationCompanyProductstrictaccording toNational StandardProduction,Quality AssuranceRegular18ProductionMonth
- ProductOutputFactoryFrontAllAfter Strict Testing,Attached withhProductCertificate of Conformity、ManualEtc.documents
- can be based on user needsprovideTechnical Support And on-siteInstallationguidance
- provideComprehensive的After-sales Service,Warranty PeriodDomesticfreerepairreplacement